10kV 20kV 35kV Cast Resin Dry Type Transformer

10kV 20kV 35kV Cast Resin Dry Type Transformer

The three-dimensional wound core resin-insulated dry-type transformer is a perfect combination of the three-dimensional wound core and the resin-insulated dry-type transformer.

Product introduction

 

The three-dimensional wound core resin-insulated dry-type transformer is a perfect combination of the three-dimensional wound core and the resin-insulated dry-type transformer.

This product not only inherits the advantages of the three-dimensional wound core, such as energy saving, material saving, low no-load loss, low no-load current and low noise, but also features excellent electrical performance, low partial discharge, high lightning impulse resistance, strong short-circuit withstand capability and high mechanical strength from the resin-insulated dry-type transformer.

It is a dual energy-saving product for both manufacturing and operation, and its application and promotion are in line with China's national energy conservation and emission reduction policies.

The production of this product utilizes 21 patented technologies developed by our company. We have also developed a full set of specialized production equipment to support its manufacturing.

This product is suitable for environments with high fire protection requirements, including high-rise buildings, airports, railway stations, ports, subways, hospitals, power plants, metallurgical industries, shopping malls, densely populated residential areas, petrochemical plants, nuclear power stations and nuclear submarines.

As a new high-tech transformer product, the three-dimensional wound core resin-insulated dry-type transformer provides an advanced solution featuring energy efficiency, environmental friendliness, excellent weather resistance and superior electrical performance.

 

Product structure

 

  • The three-dimensional triangular structure realizes a more optimized arrangement of the iron core. Three identical single-frame cores are assembled into a three-dimensional equilateral triangle, ensuring fully symmetrical and equal-length magnetic paths for the three-phase iron core, balancing three-phase power supply, significantly reducing magnetic resistance, and drastically cutting excitation current and no-load loss.
  • The iron core curing adopts the proprietary curing process exclusive to three-dimensional triangular wound cores, delivering excellent curing effect. This process guarantees no deformation of the iron core during assembly, transportation and operation, further reducing no-load loss and noise of the iron core.

 

Key Advantages of This Structure

 

1. Significant Energy Saving

The three-dimensional triangular wound core is seamless, eliminating high-energy-consumption zones. It fully leverages the high magnetic permeability of premium iron core materials, minimizing the loss caused by air gaps at joints.

2. Compact Miniaturized Design

With a high space utilization rate, the triangular structure of the transformer results in a smaller volume than conventional transformers, featuring a compact structure, attractive appearance and minimal floor space.

3. Ultra-low Noise

The three-dimensional triangular wound core is wound sequentially with trapezoidal silicon steel strips, ensuring tight lamination between strips. The magnetic permeability direction of the silicon steel strip is fully aligned with the magnetic path direction of the iron core, resulting in minimal vibration during operation. This structure effectively eliminates the noise generated by discontinuous magnetic paths in laminated cores, reducing noise to the lowest possible level.

 

Winding

 

The coil consists of a high-voltage coil and a low-voltage coil. The low-voltage coil adopts a foil or cylindrical structure, with its end insulation sealed by resin mixture. The high-voltage coil adopts a sectional cylindrical structure, and the entire coil conductor is encapsulated by a solid epoxy resin insulation layer.
According to the capacity of the transformer, axial heat dissipation ducts for bidirectional heat dissipation are arranged inside the coil.
Interlayer insulation is made of high-grade DMD prepreg and formed by hot curing. After winding processing, the product is cured in an oven to form a winding with excellent short-circuit withstand capability. Meanwhile, for transformers with a capacity of 315kVA and above, foil windings are adopted for the low-voltage side.


The low-voltage foil winding offers the following advantages:
• No helix angle at both ends of the coil, greatly reducing unbalanced ampere-turns and significantly enhancing short-circuit withstand capability.
• Winding turns are arranged along the width, allowing more flexible and applicable heat dissipation ducts and excellent heat dissipation performance.
• High inter-turn capacitance and low potential gradient, resulting in strong impulse voltage withstand capability.
The high-voltage coil adopts a sectional cylindrical structure, and the entire conductor is encapsulated by a solid epoxy resin insulation layer. High-grade insulating materials for epoxy resin and curing agent are supplied by HUNTSMAN Advanced Materials. The coil conductor and resin insulation layer form an integral rigid body with excellent mechanical strength and strong short-circuit withstand capability, as well as high dielectric strength of epoxy resin.
In addition, since the entire coil conductor is encapsulated by solid epoxy resin, moisture intrusion is effectively prevented, and the conductor is fully protected from corrosion by various harmful gases and corrosive chemicals, providing excellent moisture-proof and anti-fouling performance.

 

Electromagnetic Wire

 

Our company adopts the N758 paper-covered wire developed in cooperation with DuPont. The insulation thickness of the N758 electromagnetic wire is merely 0.16mm, while it boasts a high minimum breakdown voltage.

On the premise of meeting the electrical performance requirements of transformers, this wire can reduce the volume of transformer coils and cut down the consumption of raw materials, thus saving the usage of wire materials and silicon steel sheets. For transformers with the same capacity, adopting N758 paper-covered wire can save 0.4% of electromagnetic wire and 1% of silicon steel sheets.

Thanks to the relatively thin insulation layer of N758 paper-covered wire, the coils using this wire contribute to a smaller transformer size, as well as lower consumption of electromagnetic wire and silicon steel sheets. Therefore, N758 paper-covered wire has a more competitive price than the double glass fiber covered wire (SBEB) used in traditional epoxy resin transformers, which further enhances the economic efficiency of the transformer.

 

Vacuum Pressure Casting

 

High-voltage Casting Structure with Thin Insulation

The high-voltage winding adopts a thin-insulation casting structure, which is cast with epoxy resin mixed filler under a vacuum state of 3-5MPa. During the entire casting process, the temperature and vacuum degree of each technological procedure are strictly controlled, including baking, preheating, casting, vacuum maintenance, pressure relief, gelation, curing and demolding, so as to eliminate defects such as bubbles and cracks in the winding after casting.

The poured resin mixture can fully penetrate into all gaps of the coil, avoiding the existence of voids and effectively suppressing the occurrence of partial discharge. The partial discharge level is no more than 10pC.

 

Technical Parameter

 

1) SCB Series Epoxy Resin Casting Class F Dry-Type Transformer

Rated Capacity

(kVA)

Voltage combinations and tap range

Connection

Group symbol

SC(B)9 - RL

SC(B)10 - RL

SC(B)11 - RL

Short-circuit

Impedance

%

H.V.

(kV)

High voltage tap range %

L.V.

(kV)

No-load loss

W

Load loss 120℃

W

No-load current

(%)

No-load loss

W

Load loss 120℃

W

No-load current

(%)

No-load loss

W

Load loss 120℃

W

No-load current

(%)

30

6

6.3

10

10.5

11

±5

±2x2.5

0.4

Dyn11

Yyn0

220

750

2.4

190

710

0.6

170

710

0.6

4.0

50

80

310

1060

2.4

270

1000

0.6

240

1000

0.6

4.0

80

100

420

1460

1,8

370

1380

0.6

330

1380

0.6

4.0

100

450

1670

1.8

1.6

1.6

400

1570

0.6

360

1570

0.6

4.0

125

530

1960

1.6

1.6

1

470

1850

0.6

420

1850

0.6

4.0

160

610

2250

1.6

540

2130

0.6

480

2130

0.6

4.0

200

700

2680

1.4

620

2530

0.5

550

2530

0.5

4.0

250

6

6.3

10

10.5

11

±5

±2x2.5

0.4

Dyn11

Yyn0

810

2920

1.4

720

2760

0.5

640

2760

0.5

4.0

315

990

3670

1.2

880

3470

0.5

790

3470

0.5

4.0

400

1100

4220

1.2

980

3990

0.4

880

3990

0.4

4.0

500

1310

5170

1.2

1160

4880

0.4

1040

4880

0.4

4.0

630

1460

6220

1.0

1300

5880

0.3

1170

5880

0.3

6.0

800

1710

7360

1.0

1520

6960

0.3

1360

6960

0.3

6.0

1000

1990

8610

1.0

1770

8130

0.3

1590

8130

0.3

6.0

1250

2350

10260

1.0

2090

9690

0.25

1880

9690

0.25

6.0

1600

2760

12400

1.0

2450

11730

0.25

2200

11730

0.25

6.0

2000

3400

15300

0.8

3050

14450

0.2

2740

14450

0.2

6.0

2500

4000

18180

0.8

3600

17170

0.2

3240

17170

0.2

6.0

 

Rated Capacity

(kVA)

Voltage combinations and tap range

Connection

Group symbol

SC(B)12 - RL

SC(B)13 - RL

Short-circuit

Impedance

%

H.V.

(kV)

High voltage tap range %

L.V.

(kV)

No-load loss

W

Load loss 120℃

W

No-load current

(%)

No-load loss

W

Load loss 120℃

W

No-load current

(%)

30

6

6.3

10

10.5

11

±5

±2x2.5

0.4

Dyn11

Yyn0

150

710

2.4

130

640

0.6

4.0

50

80

215

1000

2.4

190

900

0.6

4.0

80

295

1380

1.8

260

1240

0.6

4.0

100

320

1570

1.8

280

1415

0.5

4.0

125

375

1850

1.6

330

1665

0.5

4.0

160

430

2130

1.6

380

1915

0.4

4.0

200

495

2530

1.4

440

2275

0.4

4.0

250

575

2760

1.4

510

2485

0.35

4.0

315

705

3470

1.2

630

3125

0.35

4.0

400

785

3990

1.2

700

3590

0.3

4.0

500

930

4880

1.0

830

4390

0.3

4.0

630

1070

5880

1.0

930

5290

0.25

6.0

800

1215

6960

1.0

1080

6265

0.25

6.0

1000

1415

8130

1.0

1270

7315

0.2

6.0

1250

1670

9690

1.0

1500

8720

0.2

6.0

1600

1960

11730

1.0

1760

10555

0.18

6.0

2000

2440

11450

0.8

2190

13005

0.18

6.0

2500

2880

17170

0.8

2590

15455

0.18

6.0

 

Overload capacity (transformer in forcing in forced-air cooling situation satisfies)

Over current

20

30

40

50

60

Allowed running time(hours)

60

45

32

18

5

 

Hot Tags: 10kv 20kv 35kv cast resin dry type transformer, China 10kv 20kv 35kv cast resin dry type transformer manufacturers, suppliers, factory, 35kV cast coil dry type transformer, dry resin transformer, 10kV 20kV 35kV Dry Type Transformers, SG Series Three Phase Control dry type Transformer, Three Phase Isolation Transformer, 25kV dry type transformer

Send Inquiry

(0/10)

clearall